Lead switches are a common mistake when ECGs are made and can lead to wrong diagnoses. Common mistakes are: | |||
* left - right arm reversals. This leads to a negative complex in lead I with also a negative P wave in lead I. It is one of the most common causes of right axis deviation on the ECG! | |||
* Arm - foot switches lead to a very small or 'far field' signal in leads II or III. | |||
* Chest lead reversal lead to inappropiate R wave progression (increase - decrease - increase) and are often easily recognized. | |||
<div style="float:right"> | <div style="float:right"> | ||
<gallery> | <gallery> | ||
Line 14: | Line 17: | ||
</gallery> | </gallery> | ||
</div> | </div> | ||
More specific patterns with every lead reversal: | |||
*right leg and right arm: | *right leg and right arm: | ||
**Hardly any signal in lead II. | **Hardly any signal in lead II. | ||
Line 27: | Line 30: | ||
**inversion of leads I, II and III | **inversion of leads I, II and III | ||
**reversal of leads aVR and aVF | **reversal of leads aVR and aVF | ||
It is possible to distinguish lead reversal and [[w:Dextrocardia|dextrocardia]] by watching the precordial leads. Dextrocardia will not show any R wave progression in leads V1-V6, whereas lead reversal will. | It is possible to distinguish lead reversal and [[w:Dextrocardia|dextrocardia]] by watching the precordial leads. Dextrocardia will not show any R wave progression in leads V1-V6, whereas lead reversal will. |
Revision as of 07:54, 15 October 2009
Author(s) | J.S.S.G. de Jong | |
Moderator | J.S.S.G. de Jong | |
Supervisor | ||
some notes about authorship |
Lead reversals
Lead switches are a common mistake when ECGs are made and can lead to wrong diagnoses. Common mistakes are:
- left - right arm reversals. This leads to a negative complex in lead I with also a negative P wave in lead I. It is one of the most common causes of right axis deviation on the ECG!
- Arm - foot switches lead to a very small or 'far field' signal in leads II or III.
- Chest lead reversal lead to inappropiate R wave progression (increase - decrease - increase) and are often easily recognized.
More specific patterns with every lead reversal:
- right leg and right arm:
- Hardly any signal in lead II.
- right and left arm electrodes;
- reversal of leads II and III
- reversal of leads aVR and aVL
- left arm and left leg:
- reversal of leads I and II
- reversal of leads aVR and aVF
- inversion of lead III
- right arm and left leg:
- inversion of leads I, II and III
- reversal of leads aVR and aVF
It is possible to distinguish lead reversal and dextrocardia by watching the precordial leads. Dextrocardia will not show any R wave progression in leads V1-V6, whereas lead reversal will.
Artifacts
Electrical interference from a nearby electrical appliance. A typical example is a 100 Hz background distortion from fluorescent lights. Not to be confused with atrial fibrillation.
Artifacts (disturbances) can have many causes. Common causes are:
Movement
Electrical interference