Lead switches are a common mistake when ECGs are made and can lead to wrong diagnoses. Common mistakes are:
Lead switches are a common mistake when ECGs are made and can lead to wrong diagnoses. Common mistakes are:
* left - right arm reversals. This leads to a negative complex in lead I with also a negative P wave in lead I. It is one of the most common causes of right axis deviation on the ECG!
* '''Left - right arm reversals'''. This leads to a negative complex in lead I with also a negative P wave in lead I. It is one of the most common causes of right axis deviation on the ECG!
* Arm - foot switches lead to a very small or 'far field' signal in leads II or III.
* '''Arm - foot switches''' lead to a very small or 'far field' signal in leads II or III.
* Chest lead reversal lead to inappropiate R wave progression (increase - decrease - increase) and are often easily recognized.
* '''Chest lead reversal''' lead to inappropiate R wave progression (increase - decrease - increase) and are often easily recognized.