McGill Case 96: Difference between revisions

Jump to navigation Jump to search
no edit summary
No edit summary
No edit summary
 
(One intermediate revision by the same user not shown)
Line 6: Line 6:
}}
}}


[[File:E000795.jpg|thumb|600px|left|This cardiogram shows normal VVI pacemaker function. The patient's native EKG seems relatively normal. Of interest notice the "capture beats" where the narrow complexes that are conducted through the A/V node appear earlier than the paced beats but are narrow. This suggests that there is no retrograde conduction from the ventricle to the atrium as the sinus node seems unaffected by the ventricular pacing. This is some what similar to the case of patients with VT where capture beats are seen (very rarely)]]
[[File:E000797.jpg|thumb|600px|left|]]

Navigation menu