Difficult QT: Difference between revisions

Jump to navigation Jump to search
m
No edit summary
 
(6 intermediate revisions by the same user not shown)
Line 14: Line 14:
===General considerations===
===General considerations===
* The QT interval should be measured in lead II, because the influence of a possible U-wave are smallest in this lead. If lead II is cannot be used for measurements, than leads V4 or V5 can be used alternatively.
* The QT interval should be measured in lead II, because the influence of a possible U-wave are smallest in this lead. If lead II is cannot be used for measurements, than leads V4 or V5 can be used alternatively.
* Draw a line through the baseline. This is the horizontal line between the P wave and QRS complex. If PTa depression is present, the T - P segment is used alternatively. If there is baseline drifting, it can be difficult to determine the proper baseline and measurements will be less accurate.  
* Draw a line through the baseline. This is the horizontal line between the P wave and QRS complex. If [[PTa segment]] depression is present, the T - P segment is used alternatively. If there is baseline drifting, it can be difficult to determine the proper baseline and measurements will be less accurate.  
* Draw a tangent against the steepest part of the end of the T wave. If the T wave has two humps (as in a camel back), the tallest hump should be picked. If the T wave has a positive and negative hump (or the other way around), the hump with the largest amplitude should be picked (see third example, the first hump has the largest amplitude and should be picked to draw the tangent).  
* Draw a tangent against the steepest part of the end of the T wave. If the T wave has two humps (as in a camel back), the tallest hump should be picked. If the T wave has a positive and negative hump (or the other way around), the hump with the largest amplitude should be picked (see third example, the first hump has the largest amplitude and should be picked to draw the tangent).  
* The QT interval starts at the beginning of the QRS complex: the beginning of the first deflection (either positive of negative) of the QRS complex.
* The QT interval starts at the beginning of the QRS complex: the beginning of the first deflection (either positive of negative) of the QRS complex.
* The QT interval ends where the tangent and the baseline cross.
* The QT interval ends where the tangent and the baseline cross.
* The QT interval is the time in milliseconds between the start and end of the QT interval.
* The QT interval is the time in milliseconds between the start and end of the QT interval.
* If the QRS interval exceeds 120 millisseconds, than some specialists advice to deduct the amount of milliseconds that exceeds 120 ms from the QT interval (i.e. if QRS is 140 ms and QT is 480, then 140-120ms=20ms should be deducted from the QT interval, yielding 460ms).
* If the QRS interval exceeds 120 milliseconds, than some specialists advice to deduct the amount of milliseconds that exceed 120 ms from the QT interval (i.e. if QRS is 140 ms and QT is 480, then 20ms (i.e. 140 - 120ms) should be deducted from the QT interval, yielding 460ms).


{{clr}}


===QTc is the heart rate corrected QT interval===
===QTc is the heart rate corrected QT interval===
<flash>file=QTc.swf|width=300|height=200|quality=best|align=right|salign=R||bgcolor=#FFF5F5</flash>
* The QT interval should be corrected for the heart rate, as the QT interval shortens with increasing heartrate.
* The QT interval should be corrected for the heart rate, as the QT interval shortens with increasing heartrate.
* Bazetts formula: [[Image:Formule QTc.png]], can be used to calculate the QTc: the heart rate corrected QT. When entering the formula the RR interval should be entered in seconds. The preceding RR interval should be used. You can also use this [[QTc calculator]]
* Bazetts formula: [[Image:Formule QTc.png]], can be used to calculate the QTc: the heart rate corrected QT. When entering the formula the RR interval should be entered in seconds. The preceding RR interval should be used. You can also use this [[QTc calculator]]
* Preferably one uses the average of three QTc  
* Preferably one uses the average of several QTc measurements
{{clr}}
{{clr}}


Line 36: Line 38:
#Lepeschkin pmid=14954534
#Lepeschkin pmid=14954534
</biblio>
</biblio>
<analytics uacct="UA-807577-6"></analytics>

Navigation menu