In idioventricular rhythm the rate is 30-45 bpm. The QRS complexes are wide (> 0.12 sec, often > 0.16 sec) because the ventricular signal is transmitted by cell-to-cell conduction between cardiomyocytes and not by the conduction system. | In idioventricular rhythm the rate is 30-45 bpm. The QRS complexes are wide (> 0.12 sec, often > 0.16 sec) because the ventricular signal is transmitted by cell-to-cell conduction between cardiomyocytes and not by the conduction system. | ||
[[Accelerated Idioventricuar Rhythm]] is a rapid form (60-120 bpm) of idioventricular rhythm associated with reperfusion during myocardial infarction. | |||
{{clr}} | {{clr}} |
Revision as of 15:11, 26 July 2007
This is part of: Supraventricular Rhythms |
In idioventricular rhythm the rate is 30-45 bpm. The QRS complexes are wide (> 0.12 sec, often > 0.16 sec) because the ventricular signal is transmitted by cell-to-cell conduction between cardiomyocytes and not by the conduction system.
Accelerated Idioventricuar Rhythm is a rapid form (60-120 bpm) of idioventricular rhythm associated with reperfusion during myocardial infarction.