[[File:E00031351.jpg|thumb|600px|left|This is from a patient with a Medtronic Activitrax VVI.R pacer that was being replaced as it was at end of life. The pacer was to be replaced with a CPI 940 DDD pacer which was implanted via a right subclavian approach and set at a lower rate of 65/min. The VVI.R pacer was left in place (left side) and set to VVI mode and a rate of 30/min. pending explant (planned one week later).]]
 
[[File:E00031352.jpg|thumb|600px|left|]]

Latest revision as of 19:55, 17 February 2012

McGill logo.png
This case report is kindly provided by Michael Rosengarten from McGill and is part of the McGill Cases. These cases come from the McGill EKG World Encyclopedia.


Previous Case: McGill Case 134 | Next Case: McGill Case 136

This is from a patient with a Medtronic Activitrax VVI.R pacer that was being replaced as it was at end of life. The pacer was to be replaced with a CPI 940 DDD pacer which was implanted via a right subclavian approach and set at a lower rate of 65/min. The VVI.R pacer was left in place (left side) and set to VVI mode and a rate of 30/min. pending explant (planned one week later).