|Description = The patient had a Medtronic Model 8081 unipolar pacemaker implanted a few days before the cardioversion. Cardioversion was done with 50 joules with anterior and posterior pads to place the axis of the shock perpendicular to that of the pacemaker and the tip of the pacing lead.
|Category = [[Case_reports_from_Michael_Rosengarten|Case reports by Michael Rosengarten]]
|Source = EKG World Encyclopedia http://cme.med.mcgill.ca/php/index.php , courtesy of Michael Rosengarten BEng, MD.McGill
|Date = 2012
|Author = Michael Rosengarten BEng, MD.McGill
|Permission = {{by-nc-sa-3.0}}
|other_versions = None
}}

Latest revision as of 11:48, 17 February 2012

Summary

Description

The patient had a Medtronic Model 8081 unipolar pacemaker implanted a few days before the cardioversion. Cardioversion was done with 50 joules with anterior and posterior pads to place the axis of the shock perpendicular to that of the pacemaker and the tip of the pacing lead.

Category

Case reports by Michael Rosengarten

Source

EKG World Encyclopedia http://cme.med.mcgill.ca/php/index.php , courtesy of Michael Rosengarten BEng, MD.McGill

Date

2012

Author

Michael Rosengarten BEng, MD.McGill

Permission

Creative Commons Attribution Noncommercial Share-Alike License

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current11:48, 17 February 2012Thumbnail for version as of 11:48, 17 February 20123,004 × 514 (477 KB)DarrelC (talk | contribs)

The following 2 pages use this file:

Metadata