Idioventricular Rhythm: Difference between revisions
Jump to navigation
Jump to search
mNo edit summary |
No edit summary |
||
(2 intermediate revisions by one other user not shown) | |||
Line 2: | Line 2: | ||
[[Image:Rhythm_idioventricular.png|thumb|An example of idioventricular rhythm]] | [[Image:Rhythm_idioventricular.png|thumb|An example of idioventricular rhythm]] | ||
In idioventricular rhythm the rate is 30-45 bpm. The QRS complexes are wide (> 0.12 sec, often > 0.16 sec) because the ventricular signal is transmitted by cell-to-cell conduction between cardiomyocytes and not by the conduction system. | In idioventricular rhythm the rate is 30-45 bpm. The QRS complexes are wide (> 0.12 sec, often > 0.16 sec) because the ventricular signal is transmitted by cell-to-cell conduction between cardiomyocytes and not by the conduction system. | ||
[[AIVR|Accelerated idioventricuar rhythm]] is a rapid form (60-120 bpm) of idioventricular rhythm associated with reperfusion during myocardial infarction. | |||
{{clr}} | {{clr}} |
Latest revision as of 05:16, 15 August 2007
This is part of: Supraventricular Rhythms |
In idioventricular rhythm the rate is 30-45 bpm. The QRS complexes are wide (> 0.12 sec, often > 0.16 sec) because the ventricular signal is transmitted by cell-to-cell conduction between cardiomyocytes and not by the conduction system.
Accelerated idioventricuar rhythm is a rapid form (60-120 bpm) of idioventricular rhythm associated with reperfusion during myocardial infarction.