|Description = This is an electrocardiogram taken of from a patient after implantation of pacemaker.
This electrocardiogram is interesting as it comes from a patient who previously had had a ventricular lead pacing his left ventricle.
In this recording one clearly sees a QRS which now shows a left a bundle branch like configuration, suggesting that the New lead is in the right ventricle.
One can also see that the patient has what is called trifasicular block, as we can see a first-degree block, a left axis deviation, and a right to bundle branch block.
It is clear, that the pacemaker is not sensing the atrium or the ventricle. In this case, this is because a magnet was place over the pacemaker. This was required to demonstrate the QRS morphology from the paced beats as the patient's own heart rate was faster than the rate of the pacemaker.


|Category = [[Case_reports_from_Michael_Rosengarten|Case reports by Michael Rosengarten]]
|Source = EKG World Encyclopedia http://cme.med.mcgill.ca/php/index.php , courtesy of Michael Rosengarten BEng, MD.McGill
|Date = 2012
|Author = Michael Rosengarten BEng, MD.McGill
|Permission = {{by-nc-sa-3.0}}
|other_versions = None
}}

Latest revision as of 10:22, 21 February 2012

Summary

Description

This is an electrocardiogram taken of from a patient after implantation of pacemaker. This electrocardiogram is interesting as it comes from a patient who previously had had a ventricular lead pacing his left ventricle. In this recording one clearly sees a QRS which now shows a left a bundle branch like configuration, suggesting that the New lead is in the right ventricle. One can also see that the patient has what is called trifasicular block, as we can see a first-degree block, a left axis deviation, and a right to bundle branch block. It is clear, that the pacemaker is not sensing the atrium or the ventricle. In this case, this is because a magnet was place over the pacemaker. This was required to demonstrate the QRS morphology from the paced beats as the patient's own heart rate was faster than the rate of the pacemaker.

Category

Case reports by Michael Rosengarten

Source

EKG World Encyclopedia http://cme.med.mcgill.ca/php/index.php , courtesy of Michael Rosengarten BEng, MD.McGill

Date

2012

Author

Michael Rosengarten BEng, MD.McGill

Permission

Creative Commons Attribution Noncommercial Share-Alike License

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current10:08, 21 February 2012Thumbnail for version as of 10:08, 21 February 20123,004 × 1,599 (4.43 MB)DarrelC (talk | contribs)

The following page uses this file:

Metadata