Basics: Difference between revisions

Jump to navigation Jump to search
16 bytes added ,  22 January 2012
Line 292: Line 292:
*Leads to improve diagnosis in '''right ventricular en posterior infarction''':
*Leads to improve diagnosis in '''right ventricular en posterior infarction''':
In case of an inferior wall infarct, extra leads may be used:
In case of an inferior wall infarct, extra leads may be used:
:#On a right-sided ECG, V1 and V2 remain on the same place. V3 to V6 are placed on the same place but mirrored on the chest. So V4 is in the middle of the right clavicle. The ECG should be marked as a ''Right-sided ECG''. V4R (V4 but right sided) is a sensitive lead for diagnosing right ventricular infarctions.
:::: 1. On a right-sided ECG, V1 and V2 remain on the same place. V3 to V6 are placed on the same place but mirrored on the chest. So V4 is in the middle of the right clavicle. The ECG should be marked as a ''Right-sided ECG''. V4R (V4 but right sided) is a sensitive lead for diagnosing right ventricular infarctions.
:#Leads V7-V8-V9 can be used to diagnose a posterior infarct. After V6, leads are placed towards the back. See the chapter[[Ischemia]] for other ways of diagnosing posterior infarction.
 
:::: 2. Leads V7-V8-V9 can be used to diagnose a posterior infarct. After V6, leads are placed towards the back. See the chapter[[Ischemia]] for other ways of diagnosing posterior infarction.




*Leads to improve detection of '''atrial rhyhtm''':
*Leads to improve detection of '''atrial rhyhtm''':
In wide complex tachycardia, good detection of atrial rhythm and atrio-ventricular dissociation can be very helpful in the diagnosis process. An esophagal ECG electrode placed close to the atria can be helpful. Another, less invasive, method is the '''Lewis Lead'''. This is recorded by changing the limb electrodes, placing the right arm electrode in the second intercostal space and the left arm electrode in the fourth intercostal space, both to the right of the sternum. Furthermore gain is increased to 20mm/mV and paper speed to 50mm/sec.<cite>Lewis1</cite>ß
::In wide complex tachycardia, good detection of atrial rhythm and atrio-ventricular dissociation can be very helpful in the diagnosis process. An esophagal ECG electrode placed close to the atria can be helpful. Another, less invasive, method is the '''Lewis Lead'''. This is recorded by changing the limb electrodes, placing the right arm electrode in the second intercostal space and the left arm electrode in the fourth intercostal space, both to the right of the sternum. Furthermore gain is increased to 20mm/mV and paper speed to 50mm/sec.<cite>Lewis1</cite>ß
 
*Lead positioning to enhance detection of [[Brugada]] syndrome
*Lead positioning to enhance detection of [[Brugada]] syndrome
{{clr}}
{{clr}}
25

edits

Navigation menu