McGill Case 267

From ECGpedia
Revision as of 21:09, 19 February 2012 by DarrelC (talk | contribs) (Created page with "{{McGillcase| |previouspage= McGill Case 266 |previousname= McGill Case 266 |nextpage= McGill Case 268 |nextname= McGill Case 268 }} [[File:E267.jpg|thumb|600px|left|These t...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
McGill logo.png
This case report is kindly provided by Michael Rosengarten from McGill and is part of the McGill Cases. These cases come from the McGill EKG World Encyclopedia.


Previous Case: McGill Case 266 | Next Case: McGill Case 268

These two rhythm strips show Mobitz I A/V block with a gradual increase in the PR interval before the dropped p wave. Note the 2:1 block in the lower strip, and that one can not use this to determine if the block is Mobitz I or II as more than one conducted P wave is required to do this.