Puzzle Syncopated Rhythm - Answer

Revision as of 20:28, 7 October 2007 by Drj (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Author(s) L.R.C. Dekker, R. Tukkie
NHJ edition: 2007:4,157
These Rhythm Puzzles have been published in the Netherlands Heart Journal and are reproduced here under the prevailing creative commons license with permission from the publisher, Bohn Stafleu Van Loghum.
The ECG can be enlarged twice by clicking on the image and it's first enlargement

A 65-year-old woman was admitted because of recurrent syncope. Her complaints were difficult to interpret due to mental impairment after cerebral haemorrhage ten years earlier. She was once found lying in the street after walking her dog. Her medical history further included congestive heart failure after several untreated myocardial infarctions and diabetes. Under treatment with oral antidiabetics, furosemide, ACE inhibitor, digoxin and aspirin, she was in functional NYHA class I/IV. A 12-lead ECG is shown in figure 1.

Figure 1
Figure 2

What is the most likely level of this 2:1 AV block and what explains the p-wave pattern?

Answer

This is a typical example of ventriculophasic sinus arrhythmia: PP intervals encompassing a QRS complex are consistently shorter than those without an intervening QRS complex. It is most likely that arterial pressure-induced changes in baroreceptor-mediated vagal input to the sinus node underlie this phenomenon.

Obviously, one cannot be absolutely certain about the level of the 2:1 AV block. Nevertheless, there are several clues. The QRS duration is 160 ms and QRS axis is about -45o indicating peripheral conduction disturbance and, thus, block at the infra-His level. Also, the fact that this case involves a symptomatic, female patient older than 60 years with structural heart disease favours infra-nodal disease.

The PR interval is prolonged at 240 ms. In the presence of a narrow QRS complex this would have been suggestive of an AV nodal conduction disturbance. In this case, however, the QRS is prolonged and coexistence of nodal delay cannot be ruled out. As discontinuation of digoxin did not affect the PR interval, it is concluded that severe impairment of intraor infra-His conduction is the cause of the long PR interval. She became free of symptoms after implantation of a DDD pacemaker.