File:E0003140.jpg

Revision as of 22:38, 18 February 2012 by DarrelC (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Original file(3,004 × 564 pixels, file size: 609 KB, MIME type: image/jpeg)

Summary

Description

A magnet was placed over the pacemaker that was set at 30/min. and hence it is paceing at 30/min and is not affected by the native sinus beats. This and interesting case of group beating. The sinus beats are locked into the step with the ventricular pacemaker and suggests an effect of the ventricular paced complex on the sinus node, perhaps as seen with the ventriculophasic effect.

Category

Case reports by Michael Rosengarten

Source

EKG World Encyclopedia http://cme.med.mcgill.ca/php/index.php , courtesy of Michael Rosengarten BEng, MD.McGill

Date

2012

Author

Michael Rosengarten BEng, MD.McGill

Permission

Creative Commons Attribution Noncommercial Share-Alike License

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current22:38, 18 February 2012Thumbnail for version as of 22:38, 18 February 20123,004 × 564 (609 KB)DarrelC (talk | contribs)

The following page uses this file:

Metadata